Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.865
Filtrar
1.
BMC Vet Res ; 20(1): 154, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658930

RESUMO

BACKGROUND: In people, obesity is a risk factor for cardiovascular disease, associated with systemic hypertension, cardiac remodelling and systolic and diastolic dysfunction. Weight reduction can reverse myocardial remodelling and reduce risk of subsequent cardiovascular disease. In cats, far less is known regarding the effects of obesity and subsequent weight reduction on cardiovascular morphology and function. This prospective study aimed to assess cardiac morphology and function, heart rate variability, cardiac biomarkers and body composition before and after controlled weight reduction in cats with obesity. Body composition analysis (by dual energy x-ray absorptiometry, DEXA) and cardiovascular assessment (echocardiography, systemic arterial systolic blood pressure, electrocardiography, plasma cardiac biomarkers) were performed prior to weight management in twenty cats with obesity. These investigations were repeated in eleven cats that reached target weight. RESULTS: At baseline, systemic hypertension was not documented, but the majority of cats with obesity (15 out of 19) showed echocardiographic evidence of diastolic dysfunction. Eleven of 20 cats had increased maximal end-diastolic septal or left ventricular free wall thickness (≥ 6.0 mm) at baseline. Median (interquartile range) percentage of weight lost in the cats reaching target weight was 26% (17-29%), with a median reduction in body fat mass of 45% (26-64%). Both the end-diastolic left ventricular free wall (median magnitude of change -0.85 mm, IQR -0.05 mm to -1.55 mm, P = 0.019; median percentage reduction 14.0%) and end-diastolic interventricular septum (median magnitude of change -0.5 mm, IQR -0.2 mm to -1.225 mm, P = 0.047; median percentage reduction 7.9%) thickness decreased after weight reduction. Following weight reduction, pulsed wave tissue Doppler imaging of the left ventricular free wall was consistent with improved diastolic function in 4 out of 8 cats, however there was no significant difference in overall diastolic function class. Further, there was no change in heart rate variability or cardiac biomarkers with weight reduction. CONCLUSION: An increase in left ventricular wall thickness and diastolic dysfunction were common echocardiographic features in cats with obesity within our study and may be reversible with successful weight and fat mass loss. Further studies are required to clarify the clinical consequences of these findings.


Assuntos
Composição Corporal , Doenças do Gato , Ecocardiografia , Obesidade , Redução de Peso , Animais , Gatos , Obesidade/veterinária , Obesidade/fisiopatologia , Masculino , Doenças do Gato/fisiopatologia , Doenças do Gato/diagnóstico por imagem , Feminino , Ecocardiografia/veterinária , Estudos Prospectivos , Frequência Cardíaca , Pressão Sanguínea , Coração , Biomarcadores/sangue , Eletrocardiografia/veterinária
2.
J Equine Vet Sci ; 135: 105048, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494096

RESUMO

The digital stethoscope (DS) is a cost-effective single-lead digital stethoscope that allows simultaneous electrocardiographic (ECG) and phonocardiographic recordings on a smartphone. Despite its application in small animals and horses, there are currently no studies on its use in donkeys. The aim of this study was to evaluate the use of a new smartphone-based DS device in recording ECG tracings in donkeys. Standard base-apex lead ECG (sECG) and single-lead DS ECG (dECG) were simultaneously recorded for at least 30 s. Both sECG and dECG tracings were analysed by the same operator, recording heart rate, ECG waves and intervals, and the presence and duration of artefacts. Thirty-seven donkeys were included. The dECG tracings were interpretable in all the animals (100 %). The results showed perfect agreement between the sECG and dECG data for the classification of heart rhythm and P-wave polarity. Strong agreement was found in the evaluation of heart rate calculated manually and automatically by the smartphone app, QRS complex polarity, T wave polarity, and duration of the PR interval. However, no agreement was found in the evaluation of P wave duration, QRS complex duration and amplitude, and T wave duration and amplitude. In conclusion, although this is only a preliminary study, the DS was a valid, practical, and easy to use electrocardiographic tool for recording good-quality ECG tracings to assess the ECGs of donkeys in the field.


Assuntos
Doenças dos Cavalos , Estetoscópios , Cavalos , Animais , Equidae , Estetoscópios/veterinária , Eletrocardiografia/veterinária , Eletrocardiografia/métodos , Arritmias Cardíacas/veterinária , Smartphone
3.
Can Vet J ; 65(3): 245-249, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38434162

RESUMO

Objective: Several skin preparation techniques are used in electrocardiogram (ECG) monitoring of horses. The objective of this study was to determine which methods produce the greatest signal quality using textile electrodes and standard silver/silver chloride (Ag/AgCl) electrodes. Animals and samples: Electrocardiogram data were collected using textile and Ag/AgCl electrodes simultaneously for 4 skin preparation techniques in 6 horses. Procedure: The effects of skin preparation (cleansing with isopropyl alcohol, with or without shaving the hair) and the effects of the application of a conductive gel were assessed using metrics of signal quality. Results: Shaving and cleansing with alcohol had no effect on signal quality for either electrode type. The Ag/AgCl electrodes contain a solid gel, and the application of additional gel did not affect signal quality. Data quality was significantly improved when gel was applied to textile electrodes. Furthermore, there was no difference in signal quality between electrode types when gel was used. Conclusion and clinical relevance: This study suggests that skin preparation by cleansing and/or shaving does not have a significant effect on equine ECG signal quality. When gel is used, textile electrodes are a practical alternative for Ag/AgCl electrodes, as they produce ECG recordings of the same quality.


Impact de la méthode de préparation de la peau sur la qualité de l'électrocardiogramme chez le cheval. Objectif: Plusieurs techniques de préparation de la peau sont utilisées lors de la surveillance électrocardiographique (ECG) des chevaux. L'objectif de cette étude était de déterminer quelles méthodes produisent la meilleure qualité de signal en utilisant des électrodes textiles et des électrodes standard argent/chlorure d'argent (Ag/AgCl). Animaux et échantillons: Les données d'électrocardiogramme ont été obtenues simultanément à l'aide d'électrodes textiles et d'électrodes Ag/AgCl pour 4 techniques de préparation cutanée chez 6 chevaux. Procédure: Les effets de la préparation de la peau (nettoyage à l'alcool isopropylique, avec ou sans rasage des cheveux) et les effets de l'application d'un gel conducteur ont été évalués à l'aide de métriques de qualité du signal. Résultats: Le rasage et le nettoyage à l'alcool n'ont eu aucun effet sur la qualité du signal pour les deux types d'électrodes. Les électrodes Ag/AgCl contiennent un gel solide et l'application de gel supplémentaire n'a pas affecté la qualité du signal. La qualité des données a été considérablement améliorée lorsque le gel a été appliqué sur des électrodes textiles. De plus, il n'y avait aucune différence dans la qualité du signal entre les types d'électrodes lorsque du gel était utilisé. Conclusion et pertinence clinique: Cette étude suggère que la préparation de la peau par nettoyage et/ou rasage n'a pas d'effet significatif sur la qualité du signal ECG équin. Lorsque du gel est utilisé, les électrodes textiles constituent une alternative pratique aux électrodes Ag/AgCl, car elles produisent des enregistrements ECG de même qualité.(Traduit par Dr Serge Messier).


Assuntos
2-Propanol , Eletrocardiografia , Compostos de Prata , Animais , Cavalos , Eletrocardiografia/veterinária , Etanol
4.
Vet Rec ; 194(6): e3857, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38379246

RESUMO

BACKGROUND: Brachycephalic dogs with pulmonary stenosis are known to have a higher incidence of concurrent coronary artery abnormalities than non-brachycephalic breeds, which increases risk when performing balloon valvuloplasty. The use of ECG-gated CT angiography has been reported for the evaluation of coronary arteries in normal dogs and dogs with pulmonary stenosis. The purpose of this study was to report findings of coronary artery origination and morphology of main branches using ECG-gated CT angiography in brachycephalic dogs with pulmonary stenosis. METHODS: An ECG-gated CT angiographic protocol was used to image coronary artery anatomy in nine brachycephalic dogs with pulmonary stenosis. Images were assessed for quality as well as coronary artery morphology by one veterinary radiologist, one veterinary cardiologist and one veterinary radiology resident. RESULTS: All nine dogs had good to excellent image quality. Coronary artery anomalies were identified in three of nine dogs: one R2A anomaly, one L2A anomaly and one L2C anomaly. Two dogs were assessed to be poor balloon valvuloplasty candidates based on CT angiographic images. LIMITATION: Coronary artery morphology was not confirmed via postmortem examination in all patients. CONCLUSION: ECG-gated CT angiography is a minimally invasive imaging modality capable of diagnosing various coronary artery anomalies in brachycephalic dogs with pulmonary stenosis and aiding in the determination of patient candidacy for balloon valvuloplasty.


Assuntos
Craniossinostoses , Doenças do Cão , Cardiopatias Congênitas , Estenose da Valva Pulmonar , Cães , Animais , Angiografia por Tomografia Computadorizada/veterinária , Vasos Coronários , Angiografia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/veterinária , Cardiopatias Congênitas/veterinária , Craniossinostoses/veterinária , Eletrocardiografia/veterinária , Doenças do Cão/diagnóstico por imagem
5.
J Vet Cardiol ; 51: 188-194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38168659

RESUMO

INTRODUCTION/OBJECTIVES: Juvenile ventricular arrhythmias in the absence of structural heart disease have been characterized in a small number of canine breeds with limited long-term follow up. The objective of this study was to describe the clinical outcome of dogs with JVA presenting to a university teaching hospital. ANIMALS, MATERIALS, METHODS: Twenty five dogs, less than two years old with idiopathic ventricular arrhythmias were retrospectively identified via a medical record search. Young dogs with ventricular arrhythmias were excluded if they had structural heart disease, systemic illness, or an abnormal troponin (if performed). Electrocardiographic and Holter monitor data was evaluated for arrhythmia frequency and complexity at the time of diagnosis and over time. Long-term follow up was achieved through client and primary veterinarian contact. RESULTS: Breeds included German Shepherd (eight), Boxer (four), Great Dane (three), mixed breed (two) and one each of the following: Anatolian Shepherd, French Bulldog, golden retriever, Great Pyrenees, Labrador retriever, Shiloh Shepherd, miniature Poodle and Siberian Husky. The average age at diagnosis was 7.9 months (range, 2-22 months). The overall median survival was 10.96 years (range, 1.75-15.66 years). There was an average reduction in the number of ventricular beats by 86.7 % per year (P value -0.0257) based on Holter data. CONCLUSION: In most cases, idiopathic juvenile ventricular arrhythmias had a favorable long-term prognosis with reduced ectopy over time in this case series. Juvenile ventricular arrhythmias remains a diagnosis of exclusion but can be considered in a broader range of dog breeds than previously described.


Assuntos
Doenças do Cão , Humanos , Cães , Animais , Estudos Retrospectivos , Doenças do Cão/diagnóstico , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/veterinária , Eletrocardiografia Ambulatorial/veterinária , Eletrocardiografia/veterinária
6.
J Vet Cardiol ; 51: 207-213, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38198978

RESUMO

A one-year-and-seven-month-old, 28 kg, male castrated crossbreed dog was presented for supraventricular tachycardia causing recurrent episodes of anorexia and lethargy. Sotalol (2.2 mg/kg q12 h) reduced the frequency of symptomatic episodes but did not provide full relief. Three-dimensional electroanatomical mapping was performed at the Ghent University Small Animal Teaching hospital using the CARTO 3. Right atrial activation mapping identified the earliest atrial activation right posteroseptal, near the tricuspid annulus. Fast retrograde ventriculoatrial conduction during tachycardia and extrastimulus testing confirmed the presence of a concealed right posteroseptal accessory pathway. Six radiofrequency catheter ablation applications were delivered, and tachycardia remained uninducible. The dog recovered well from the procedure. Sotalol was stopped three weeks later, and no more clinical signs were noted by the owner. Repeated 24-hour electrocardiography monitoring on day one and at one, three, and 12 months after the procedure showed no recurrence of tachycardia.


Assuntos
Ablação por Cateter , Doenças do Cão , Taquicardia Supraventricular , Humanos , Masculino , Cães , Animais , Sistema de Condução Cardíaco , Sotalol , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/veterinária , Taquicardia/cirurgia , Taquicardia/veterinária , Eletrocardiografia/veterinária , Ablação por Cateter/veterinária , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/cirurgia
7.
Am J Vet Res ; 85(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37984068

RESUMO

OBJECTIVE: The Lewis lead is an EGC configuration used to detect atrial activity and its relationship with ventricular activity. However, no equivalent configuration has been proposed in veterinary medicine. Therefore, this study explored new bipolar lead configurations to evaluate atrial depolarization and investigated their characteristics by comparing them with conventional leads. The authors hypothesized that a lead with a high absolute value of the P wave (|P|) and a high ratio of the P wave to the QRS complex (|P|/|QRS|) might be an appropriate configuration. ANIMALS: 6 laboratory Beagles were used. PROCEDURES: Electrocardiograms were recorded using bipolar limb leads (I, II, III, aVL, aVF, and aVR) and unipolar precordial leads (C2, C3, C4, C5, C6, M1, M2, M5, M6, 1st-R, CV6LL, and V10) in the standing position. The new bipolar leads were attached in the following configuration: the negative electrode was attached to M6, and the positive electrode was sequentially applied to M1 and M2. The leads were named M6M1 and M6M2. RESULTS: The waveforms obtained using the new bipolar leads M6M1 and M6M2 showed significantly higher |P|/|QRS| and |P| values than those obtained using conventional limb leads and precordial leads. CLINICAL RELEVANCE: The new leads achieved a specific enhancement of atrial activity conducted at a reduced ventricular amplitude and increased atrial amplitude, similar to the Lewis lead in human medicine. These findings suggest that M6M1 and M6M2 could be supplemental lead configurations to identify P waves without amplifying the QRS waves compared to conventional methods.


Assuntos
Eletrocardiografia , Humanos , Animais , Cães , Eletrocardiografia/veterinária , Eletrodos
8.
Vet J ; 303: 106043, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37992801

RESUMO

Smartphone-based technology for electrocardiographic recording is now part of the new concept of mobile health in both human and veterinary medicine. Although smartphone-based ECG for electrocardiographic screening in dogs is reliable, one-lead ECG devices have mainly been evaluated. This prospective study assessed the feasibility and the diagnostic reliability of a new smartphone-based six-lead electrocardiograph (smECG) in dogs, in comparison to a standard six-lead electrocardiograph (stECG). All ECG tracings were blindly reviewed by an expert operator, who judged whether tracings were acceptable for interpretation, performed the electrocardiographic measurements, and assigned a diagnosis. The agreement in the electrocardiographic interpretation and diagnosis between smECG and stECG was assessed using the Bland-Altman test and Cohen's k test. The study included 108 client-owned dogs. The tracings obtained by the smECG were interpretable in 100 % of cases. No clinically relevant differences between smECG and stECG were found in the assessment of heart rate, interval duration, and QRS mean electrical axis. The smECG tended to underestimate the amplitude of the P and R waves. Perfect agreement was found in the detection of sinus rhythm, atrial fibrillation, ventricular arrhythmias, atrioventricular blocks, and bundle branch blocks. Our study suggests that the tested smartphone-based six-lead ECG is a clinically reliable device for the assessment of heart rate and heart rhythm in dogs, and thus could be used in a clinical setting in dogs and for telemedicine.


Assuntos
Fibrilação Atrial , Doenças do Cão , Humanos , Cães , Animais , Smartphone , Estudos Prospectivos , Reprodutibilidade dos Testes , Eletrocardiografia/veterinária , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/veterinária , Doenças do Cão/diagnóstico
9.
J Vet Cardiol ; 51: 116-123, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128417

RESUMO

OBJECTIVES: The purpose of this study was to describe the frequency of arrhythmias detected in unsedated feline patients from general practice settings. ANIMALS: A total 10,638 feline electrocardiograms (ECGs) were retrospectively collected of which 9440 met the inclusion criteria. METHODS: Recordings were evaluated by a board-certified cardiologist. If an arrhythmia was present in the ECG tracing, the cardiologist categorized the arrhythmia using pre-established keywords. RESULTS: At least one arrhythmia was observed in 249 cases (2.64%, 95% confidence interval (CI): 2.34-2.98, 249/9440), with the most common arrhythmia encountered being ventricular premature complexes (1.63%, 95% CI: 1.39%-1.91%, 154/9440). Ragdoll cats had the highest odds of arrhythmia (odds ratio (OR): 3.17, 95% CI: 1.43-6.17, P=0.036). Both geriatric (Age: 13+ years, OR: 1.70, 95% CI: 1.24-2.34, P=0.013) and senior (Age: 10-13 years, OR: 1.68, 95% CI: 1.19-2.37, P=0.003) cats had higher odds of having an arrhythmia than adult cats. The odds of male cats having an arrhythmia were slightly higher than female (OR: 1.36, 95% CI: 1.06-1.76, P=0.018). CONCLUSIONS AND RELEVANCE: Of the 9440 ECGs included in this study, at least one arrhythmia was detected in 249 distinct cases. Arrhythmias were more common in older cats, male cats and the Ragdoll cat breed. While it is important to note that the presence of an arrhythmia alone does not always indicate the presence of heart disease, further research on the association between breed cardiac health is needed.


Assuntos
Doenças do Gato , Cardiopatias , Complexos Ventriculares Prematuros , Gatos , Masculino , Animais , Feminino , Estudos Retrospectivos , Eletrocardiografia/veterinária , Coração , Complexos Ventriculares Prematuros/veterinária , Cardiopatias/veterinária , Doenças do Gato/diagnóstico , Doenças do Gato/epidemiologia
10.
J Vet Cardiol ; 50: 1-16, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37913604

RESUMO

INTRODUCTION: Cavalier King Charles Spaniels (CKCS) are predisposed to developing myxomatous mitral valve disease (MMVD). Dogs with stage B2 MMVD benefit from medication. OBJECTIVES: To develop (1) breed-specific cut-offs for individual screening tests and (2) predictive models utilizing physical examination (PE), ECG, radiograph, and blood-based biomarker variables in combination for identification of echocardiographic stage B2 MMVD in preclinical CKCS. ANIMALS: Adult, preclinical CKCS not receiving cardiac medications (N = 226). MATERIALS AND METHODS: Prospective, cross-sectional study. Enrolled CKCS underwent PE, ECG, radiography, Doppler blood pressure measurement, echocardiography, and biomarker testing. Dogs were grouped by MMVD stage using echocardiography only. The discriminatory ability of individual tests to identify stage B2 was assessed, and prediction models were developed using variables derived from four 'tests' (PE, ECG, radiography, and biomarkers). RESULTS: N-terminal pro-B-type natriuretic peptide (NT-proBNP) and radiographic vertebral heart size (VHS) had the best discriminatory ability of individual diagnostic tests to differentiate stage A/B1 CKCS from stage B2, with an area under the curve (AUC) of 0.855 and 0.843, respectively. An NT-proBNP ≥1138 pmol/L or a VHS ≥11.5 had high specificity for predicting stage B2 (90.1% and 90.6%, respectively). Prediction models incorporating variables from multiple tests had better discriminatory ability than single tests. The four-test prediction model had an AUC of 0.971. Three and two-test models had AUCs ranging between 0.925-0.959 and 0.895-0.949, respectively. CONCLUSIONS: Both NT-proBNP and VHS have good utility for predicting echocardiographic stage B2 MMVD in CKCS as individual tests. Prediction models incorporating multiple test variables have superior discriminatory ability.


Assuntos
Doenças do Cão , Doenças das Valvas Cardíacas , Cães , Animais , Valva Mitral , Estudos Prospectivos , Estudos Transversais , Doenças do Cão/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/veterinária , Ecocardiografia/veterinária , Eletrocardiografia/veterinária , Radiografia , Exame Físico , Biomarcadores
11.
J Vet Intern Med ; 37(6): 1992-2002, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37715347

RESUMO

BACKGROUND: Supraventricular tachycardias (SVTs), despite having various anatomical substrates and pathophysiological mechanisms, frequently show similar electrocardiographic presentations. OBJECTIVES: To locate and characterize atrial deflections (ADs) on 12-lead electrocardiograms in dogs with sustained rapid SVT and assess the utility of different electrocardiographic variables in differentiating types of tachycardia. ANIMALS: Ninety-two dogs with orthodromic atrioventricular reciprocating tachycardia, 17 with atrial flutter, 33 with focal atrial tachycardia recorded and confirmed by electrophysiological study, and 40 dogs with sinus tachycardia. METHODS: Atrial deflection position on the 12-lead surface electrocardiogram was assessed according to the sequence of intracardiac activation. Its features were evaluated together with the relationship between AD and QRS complex interval (AD-R) and QRS complex and AD interval (R-AD). RESULTS: Orthodromic atrioventricular reciprocating tachycardia was characterized by an AD-AD interval of 213 ± 30 ms, mean electrical axis (MEA) of AD of -90 (-90/-78)°, R-AD interval of 75 (65-80) ms, and R-AD/AD-R of 0.54 (0.45-0.64). Atrial flutter was characterized by an AD-AD interval of 199 ± 57 ms, MEA of 76° (72/81), R-AD of 120 (72-144) ms, and R-AD/AD-R of 0.81 (0.63-1.13). Focal atrial tachycardia was characterized by an AD-AD interval of 270 ± 38 ms, MEA of 49 (-72/76)°, R-AD of 160 (120-200) ms, and R-AD/AD-R of 1.45 (0.92-1.67). Sinus tachycardia was characterized by an AD-AD interval of 292 ± 31 ms, MEA of 66° (52/73), R-AD of 215 (192-222) ms, and R-AD/AD-R of 2.68 (2.25-3.08). CONCLUSIONS AND CLINICAL IMPORTANCE: Analyzing AD on 12-lead electrocardiogram is helpful in differentiating the most common SVTs in dogs.


Assuntos
Flutter Atrial , Doenças do Cão , Taquicardia Reciprocante , Taquicardia Supraventricular , Cães , Animais , Flutter Atrial/veterinária , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/veterinária , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/veterinária , Taquicardia/veterinária , Eletrocardiografia/veterinária , Taquicardia Reciprocante/veterinária , Doenças do Cão/diagnóstico
12.
J Vet Med Sci ; 85(10): 1063-1067, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37599067

RESUMO

Hyperkalemia is a common electrolyte abnormality frequently complicated with chronic kidney disease. By injecting potassium chloride (KCl) solutions intravenously into bullfrogs, we reproduced typical electrocardiogram (ECG) abnormalities of hyperkalemia in the frog hearts, such as the peaked T waves and the widening of QRS complexes. Simultaneous recordings of cardiac action potentials showed morphological changes that synchronized with those of ECG. After 100 mM KCl injection, the widened QRS complexes continued for a while and gradually restored to their baseline widths. However, pre-treatment with sodium bicarbonate or salbutamol, which directly or indirectly stimulates Na+/K+-ATPase activity, significantly facilitated the recovery from the widened QRS duration, indicating the transcellular movement of potassium ions from the extracellular fluid into the intracellular stores.


Assuntos
Hiperpotassemia , Animais , Hiperpotassemia/induzido quimicamente , Hiperpotassemia/tratamento farmacológico , Hiperpotassemia/veterinária , Bicarbonato de Sódio/uso terapêutico , Rana catesbeiana , Albuterol/uso terapêutico , Potássio , Cloreto de Potássio , Eletrocardiografia/veterinária
13.
J Exp Biol ; 226(17)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37599599

RESUMO

Captive housed non-human primates, specifically great apes such as chimpanzees (Pan troglodytes) are frequently reported to have died from or are diagnosed with potentially fatal heart conditions that require the monitoring of physiological signals such as electrocardiogram (ECG) or respiratory rate. ECG screening must be conducted after applying full anaesthesia, causing potential physical and emotional stress as well as risk for the animal. Here, we present an electronic system that simultaneously measures the ECG and the electrical bioimpedance for the early detection of abnormal cardiovascular activity. Modified gloves whose fingers are equipped with electrodes enable the caregiver to obtain three cardiovascular signals (ECG, pulse rate and respiratory rate) by placing the fingertips on specific parts of the non-human primate without needing any prior physical preparations. Validation (ECG and bioimpedance) was performed both on humans and on captive housed chimpanzees, where all the signals of interest were correctly acquired.


Assuntos
Anestesia , Pan troglodytes , Animais , Humanos , Primatas , Eletrocardiografia/veterinária , Coração
15.
J Vet Med Sci ; 85(8): 828-831, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37302820

RESUMO

Effects of body size reduction on electrocardiographic indices were examined using microminipigs in comparison with Clawn miniature swine (Clawn). Electrocardiogram was recorded using Holter electrocardiograph in conscious state for 24 hr for microminipigs (male: 11.6 ± 0.1 kg, 12-17 months, n=5; and female: 9.9 ± 0.4 kg, 6 months, n=5) and Clawn (female: 20.3 ± 0.4 kg, 8-9 months, n=8). Microminipig had shorter PR interval and QRS width than Clawn, whereas no significant difference was detected in JTcF/QTcF between them. Ratios of PR interval, QRS width, and body weight cubic root for microminipigs to Clawn ranged between 0.713 and 0.830. These findings indicate that PR interval and QRS width will depend on distance for excitatory current propagation, whereas JTcF/QTcF may be governed by local electrical activities.


Assuntos
Eletrocardiografia , Doenças dos Suínos , Suínos , Masculino , Feminino , Animais , Porco Miniatura , Eletrocardiografia/veterinária , Arritmias Cardíacas/veterinária , Tamanho Corporal , Miniaturização
16.
J Vet Cardiol ; 47: 70-82, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37267820

RESUMO

OBJECTIVES: Atrioventricular accessory pathways are abnormal electrical connections between the atria and ventricles that predispose to ventricular pre-excitation (VPE) and tachycardias. ANIMALS: Seventeen cats with VPE and 15 healthy matched-control cats. MATERIAL AND METHODS: Multicenter case-control retrospective study. Clinical records were searched for cats with VPE, defined as preserved atrioventricular synchrony, reduced PQ interval, and increased QRS complex duration with a delta wave. Clinical, electrocardiography, echocardiographic, and outcome data were collated. RESULTS: Most cats with VPE were male (16/17 cats), non-pedigree cats (11/17 cats). Median age and mean body weight were 5.4 years (0.3-11.9 years) and 4.6 ± 0.8 kg, respectively. Clinical signs at presentation included lethargy (10/17 cats), tachypnea (6/17 cats), and/or syncope (3/17 cats). In two cats, VPE was an incidental finding. Congestive heart failure was uncommon (3/17 cats). Nine (9/17) cats had tachyarrhythmias: 7/9 cats had narrow QRS complex tachycardia and 2/9 cats had wide QRS complex tachycardia. Four cats had ventricular arrhythmias. Cats with VPE had larger left (P < 0.001) and right (P < 0.001) atria and thicker interventricular septum (P = 0.019) and left ventricular free wall (P = 0.028) than controls. Three cats had hypertrophic cardiomyopathy. Treatment included different combinations of sotalol (5/17 cats), diltiazem (5/17 cats), atenolol (4/17 cats), furosemide (4/17 cats), and platelet inhibitors (4/17 cats). Five cats died, all from cardiac death (median survival time 1882 days [2-1882 days]). CONCLUSIONS: Cats with VPE had a relatively long survival, albeit showing larger atria and thicker left ventricular walls than healthy cats.


Assuntos
Doenças do Gato , Síndromes de Pré-Excitação , Síndrome de Wolff-Parkinson-White , Masculino , Gatos , Animais , Feminino , Síndrome de Wolff-Parkinson-White/veterinária , Estudos Retrospectivos , Síndromes de Pré-Excitação/diagnóstico , Síndromes de Pré-Excitação/veterinária , Taquicardia/veterinária , Eletrocardiografia/veterinária , Doenças do Gato/diagnóstico por imagem
17.
J Vet Cardiol ; 47: 83-88, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37269789

RESUMO

A 13-year-old female spayed border collie cross presented for pericardial effusion, arrhythmia, and a suspected cardiac mass. Echocardiogram revealed severe thickening and hypokinesis of the interventricular septum with a heterogenous, cavitated myocardium, concerning for neoplasia. Electrocardiogram revealed predominantly accelerated idioventricular rhythm with frequent periods of nonsustained ventricular tachycardia. Occasional prolonged PR intervals terminating in an aberrantly conducted QRS complex were present. These beats were postulated to represent either first-degree atrioventricular block with aberrant QRS conduction or atrioventricular dissociation. Cytology of the pericardial effusion revealed atypical, suspected neoplastic, mast cells. The patient was euthanized, and postmortem examination confirmed full-thickness infiltration of the interventricular septum by a mast cell tumor, with metastasis to the tracheobronchial lymph node and spleen. Given the anatomic location of the mass, the observed atrioventricular nodal conduction delay may represent neoplastic infiltration of the atrioventricular node. Neoplastic infiltration of the ventricle was suspected to cause the accelerated idioventricular rhythm and ventricular tachycardia. To the authors' knowledge, this is the first reported case of a primary cardiac mast cell tumor causing arrhythmia and pericardial effusion in a dog.


Assuntos
Ritmo Idioventricular Acelerado , Bloqueio Atrioventricular , Doenças do Cão , Derrame Pericárdico , Taquicardia Ventricular , Feminino , Cães , Animais , Mastócitos/patologia , Derrame Pericárdico/veterinária , Derrame Pericárdico/complicações , Ritmo Idioventricular Acelerado/complicações , Ritmo Idioventricular Acelerado/veterinária , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/veterinária , Bloqueio Atrioventricular/veterinária , Eletrocardiografia/veterinária , Taquicardia Ventricular/veterinária , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/etiologia
18.
Vet Rec ; 193(7): e2879, 2023 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-37126211

RESUMO

BACKGROUND: No previous study has evaluated the accuracy of a six-lead smartphone-based electrocardiographic (s-ECG) device in dogs. METHODS: This was a prospective multicentre study. Patients referred for cardiologic consultation were selected. In each patient, a 30-second electrocardiogram was simultaneously acquired with a novel six-lead s-ECG and a standard six-lead ECG machine (st-ECG). A board-certified cardiologist evaluated each recording. Nineteen ECG variables, including heart rate and rhythm, as well as quantitative and qualitative features of waves, segments and intervals, were analysed. Agreement between s-ECG and st-ECG was evaluated using Cohen's kappa coefficient and the Bland-Altman test. RESULTS: Seventy-five dogs were enrolled, and 140 ECG tracings were analysed. There was perfect agreement between the two methodologies for heart rate and rhythm classification, both in dogs with sinus rhythm and those with pathological rhythms. Although some disagreement was found when comparing measurements of quantitative variables obtained with the s-ECG and the st-ECG, none of the differences was of clinical relevance. LIMITATIONS: The sample size was limited, and the interobserver variability was not analysed. CONCLUSION: The six-lead s-ECG studied herein is comparable to the st-ECG for heart rate and rhythm assessment, and seems clinically acceptable for the interpretation of waves, segments and intervals in dogs.


Assuntos
Doenças do Cão , Smartphone , Humanos , Cães , Animais , Estudos Prospectivos , Eletrocardiografia/veterinária , Arritmias Cardíacas/veterinária , Frequência Cardíaca/fisiologia , Doenças do Cão/diagnóstico
19.
Vet J ; 295: 105987, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37141934

RESUMO

This study assessed a new smartphone-based digital stethoscope (DS) featuring simultaneous phonocardiographic and one-lead electrocardiogram (ECG) recording in dogs and cats. The audio files and ECG traces obtained by the device were compared with conventional auscultation and standard ECG. A total of 99 dogs and nine cats were prospectively included. All cases underwent conventional auscultation using an acoustic stethoscope, standard six-lead ECG, standard echocardiography and recordings with the DS. All the audio recordings, phonocardiographic files and ECG traces were then blind reviewed by an expert operator. The agreement between methods was assessed using Cohen's kappa and the Bland-Altman test. Audio recordings were considered interpretable in 90% animals. Substantial agreement was found in the diagnosis of heart murmur (κ = 0.691) and gallop sound (k = 0.740). In nine animals with an echocardiographic diagnosis of heart disease, only the DS detected a heart murmur or gallop sound. ECG traces recorded with the new device were deemed interpretable in 88 % animals. Diagnosis of heart rhythm showed moderate agreement in the identification of atrial fibrillation (k = 0.596). The detection of ventricular premature complexes and bundle branch blocks revealed an almost perfect agreement (k = 1). Overall, the DS showed a good diagnostic accuracy in detecting heart murmurs, gallop sounds, ventricular premature complexes and bundle branch blocks. A clinically relevant overdiagnosis of atrial fibrillation was found but without evidence of false negatives. The DS could represent a useful screening tool for heart sound abnormalities and cardiac arrhythmias..


Assuntos
Fibrilação Atrial , Doenças do Gato , Doenças do Cão , Estetoscópios , Complexos Ventriculares Prematuros , Gatos , Cães , Animais , Fonocardiografia/veterinária , Fibrilação Atrial/veterinária , Estetoscópios/veterinária , Complexos Ventriculares Prematuros/veterinária , Smartphone , Bloqueio de Ramo/veterinária , Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Sopros Cardíacos/diagnóstico , Sopros Cardíacos/veterinária , Eletrocardiografia/veterinária , Eletrocardiografia/métodos
20.
Vet Q ; 43(1): 1-10, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37165892

RESUMO

BACKGROUND: Evaluation of heart rate variability (HRV) is used for risk assessment in a variety of cardiac diseases including myxomatous mitral valve degeneration (MMVD). OBJECTIVES: To compare the geometric analysis of HRV using visual patterns of Poincaré plot among different classes of MMVD in dogs and to analyse the differences in beat-to-beat variability using tachograms and sequential Poincaré plots among different shapes. ANIMALS AND METHODS: Healthy and MMVD dogs were retrospectively reviewed. Five-minute ECG data was used to create Poincaré plots and shapes were compared among groups. Furthermore, a sub-analysis of 50 consecutive R-R intervals was performed. Pearson Chi-square with adjusted standardized residuals was used to compare the categorical data between groups. RESULTS: Fifteen healthy dogs and 157 dogs with MMVD were included in the study. Normal and B1 groups showed a predominance of triangular shape (73% and 60% respectively; p < 0.05). In B2 group the predominant shape was comet (40%; p < 0.05) while comet and torpedo were predominant in Ca group (41% and 36% respectively; p < 0.05). Visual geometric analysis revealed a lower dispersion of the cloud clustering towards the left lower corner of the plot with MMVD progression. Diamond and triangle revealed a lower mean heart rate compared to comet and torpedo shapes (p < 0.01). Interclass correlation between 3 observers was 0.906 (95% CI of 0.8 - 0.96). CONCLUSIONS: Poincaré plot shape changes with MMVD progression suggesting that geometrical analysis of HRV in dogs with cardiac conditions could be a useful tool in the risk assessment and further studies are warranted.


Assuntos
Doenças do Cão , Doenças das Valvas Cardíacas , Cães , Animais , Valva Mitral/diagnóstico por imagem , Estudos Retrospectivos , Doenças do Cão/diagnóstico , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/veterinária , Eletrocardiografia/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...